Unlike many word processors, vi starts up in command mode. There are benefits and disadvantages to both MATLAB and LabVIEW. The file runs and the output is reported. This is only one of six instructable in my LIRC in. For example, use the CLI for LabVIEW to automate the build process of LabVIEW applications. lib\AppBuilder. Advanced File I/O: Text Files, Binary Files, and Configuration Files. It allows the developer to take the most out of the compiler. scr, rightclick and 'ins. The vi /path/to/file command also works if the file doesn’t exist yet; Vi will create a new file and write it to the specified location when you save. National Instruments (NI), has announced the release of LabVIEW 2018 For Mac Cracked system design software. You can execute operating system commands from the MATLAB ® command line using the ! operator or the system function. When you launch LabVIEW or a stand-alone executable from the command line, you can pass user-defined arguments to the application. For example, if test. The sub-folder “Low Level” contains VIs for the following functions:. be/FTYpQNPgwAQ. Add different parameters and commands then click OK to update the sequence. Save and run the VI. 10 Last change: 16 May 2007 1 User Commands vi(1) The vi (visual) utility is a display-oriented text editor based on an underlying line editor ex. EXE to execute CASCON test and in-system programming applications from the Microsoft Windows command line. LabView is a perfect candidate for this problem as it heavily favors a graphical structure. $ top -p pid_value 28) Display task per username or UID in command line. This VI has shipped with LabVIEW since before LabVIEW 2009, but is now available in the palettes. To run an operation using the CLI for LabVIEW, execute a command with one or more of the following arguments. The presentation of the code in Labview is a visual block diagram which describes the data flow within the VI. exe" when it's called from the development environment. The Solution: Developing a platform within the LabVIEW environment that allows communication to and from any robot running the ROS with minimal effort on the part of the programmer. You can also use "run as" from the command line via Command Prompt. National Instruments' (NI) LabVIEW 2018 (Fig. If you can't find anything in Labview to read the dynnamic environment varialbles take a look at Python before buying an add on module for your version of Labview. You can have the executable run in different ways, depending on the arguments given in the command line. - For automatic builds, have VI's able to be Compiled (or whatever happens to them) from the command line and verified none of them are broken (with the broken arrow for the run button). m files to NI real-time hardware • Reuse many of your scripts created with The MathWorks, Inc. Ctrl-Up arrow. I have to develop one application to communicate with my hardware. MATLAB® software and others • Develop your. exe be run as multiple instance? What is Blocknumber and Blocksize in a DL750 ASCII Header?. Save and run the VI. The link supplied had some info on using command line commands: Using Command line Arguments:Command line arguments are parameters which follow the program to be launched at the command prompt. System Requirements for LabVIEW 8. exe LEP_AutoTest_RunAll. 10 MB (37857536 bytes). The vmstat command will display statistics about system processes, memory, swap, I/O, and the CPU performance. " Figure 1 - Opening the Command Prompt in elevated mode (clockwise from top left, Windows XP, 7, 8 & 10) 3. In other words, after starting the command window and passing the command to it, LabVIEW will continue executing the next VI in your code while the command prompt window responds to the dir command. command line indicates the command LabVIEW calls to run a program. Bruevich (Podzorov group, Rutgers U. The interpreter interface resembles that of the UNIX shell, but provides some additional methods of invocation: When called with standard input connected to a tty device, it prompts for commands and executes them until an EOF (an end-of-file character, you can produce that with Ctrl-D on UNIX or Ctrl-Z, Enter on Windows) is read. vi - parameter. If LabVIEW is not installed on your computer when the driver is installed, the LabVIEW VIs will placed in the LabVIEW6 subdirectory of the C:\Program Files\IVI Foundation\IVI\Drivers\Ke2700 directory. The LabVIEW for Raspberry Pi is a product based on LabVIEW (Laboratory Virtual Instrument Engineering Workbench) by National Instruments. In insert mode, the letters you type form words and sentences. That's why we added such command. LabVIEW Can't Find Sub-VIs. At the : prompt type the following command to run on line numbers: set number; To turn off line numbering, type the following command at the : prompt set nonumber; Let us see all commands in detailed to display line number in vim. requires a RUN command on a separate line to execute the synchronous move. - Running Operations Using the Command Line Interface for LabVIEW LabVIEW 2018 allows you to run operations in LabVIEW by executing commands using the command line interface (CLI) for LabVIEW. In TCP/IP communications, applications open a line of communication and then transfer raw data. 我使用LabVIEW System Exec VI 來運行一個MS-DOS上的程式,在這個程式(或批次檔)執行後,它會自動把命令提示字元視窗關掉。在我執行完這個程式後,我想要保持著這個視窗繼續開著,這辦得到嗎?. I don't want exchange of any data, or anything fancy. 0, Advanced Uninstaller PRO will offer to run a cleanup. This is only one of six instructable in my LIRC in. For example, the following command line entry will launch LabVIEW 7. Dot Net Error Handling Example. If you are not happy with the use of these cookies, please review our Cookie Policy to learn how they can be disabled. LIRC - LabVIEW - Sending a Remote Command From LabVIEW : This instructable will walk you through the "Send" LabVIEW VI I made for my LIRC Raspberry Pi Universal remote. To pass the command line arguments to the application and access them in your code, run the executable from the Command Prompt and add input arguments separated by spaces. Introduction to MatcScript (LabVIEW). This is a screenshot of DebugView capturing Win32 debug output from a remote system. It is very easy, then, for LabVIEW to take that selection from one screen, which we'll call the "Configure Test" screen/VI, pass that selection to a "Run Test" VI, and execute the appropriate set of code. It works but I have to control over the input to the. It consists in an executable and is able to import your existing LabVIEW application source code and add many features to your application, almost without requiring you to write any code. You can activate a 30day trial from the help menu of VIPM to try this out. LIRC - LabVIEW - Sending a Remote Command From LabVIEW : This instructable will walk you through the "Send" LabVIEW VI I made for my LIRC Raspberry Pi Universal remote. Compatible with NI LabVIEW Real-Time Module Sample Screen Shots The File Attachment (. Das größte Forum für LabVIEW-Entwickler im Raum D-A-CH. This is only one of six instructable in my LIRC in. Regards, Wiebe. Recently I was in a need to run LabVIEW VI from PowerShell while using Jenkins. vi¶ The Main. DD allows more dynamic execution and more scalable designs. vi LabVIEW VI. Using VI 3. The Timeout Event. Yes your understanding is right,I copied the property node to new vi and build the the exe. The following sections detail considerations for using LabVIEW NXG with NI-VISA. Run the version matching your system from the command line. exe file at C:\Windows\System32\cmd. vi module loaded: and below is the same module block diagram: The. PID value 0 will be treated as process ID of top command itself. If you are not happy with the use of these cookies, please review our Cookie Policy to learn how they can be disabled. vbs" "" Custom. ) 3 Some comments on device/contacts fabrication Preparing contacts to your sample. exe) as suggested in the user manual and tried to run the program. Aborts the VI, when used while VI is running. The lowercase letter "o" lets you open a new line just below your current line. After uninstalling NI LabVIEW 6. With both the Raspberry Pi 2 Model B and the Beaglebone Black, you can actually deploy your LabVIEW VIs to the board and run with a computer to visualize your data or run headlessly. in application builder. A rice-planting machine comes into wide use in this areas. Application Note Instrument Drivers LabVIEW ─ 1MA228_5e 7 Search for an entire command by placing the cursor at the end of the line and: double-click, hit F1 button or SHIFT+ENTER buttons combination. I named mine "Lift Motor" and connected it to PWM 7. When you run a command that contains the string "CMD" as the first token without an extension or path qualifier, "CMD" is replaced with the value of the COMSPEC variable. Getting Started. To access from LabView or Matlab you need only a litte interface code to exchange the command-line data with the TCL-script. The library files reside in the LabVIEW folder located in the ChipProgUSB installation directory. •Run release. Multi-line structures must include the line continuation character "{" in the same line the structure initiator (i. Related Example in Driver: Timer Calibration. Because my robot’s control system runs on a LabVIEW real-time machine, I have no recourse but to add new features in LabVIEW. Run Continuously—Runs the VI until you abort or pause execution. Need a way to visualize VI call chain hierarchy in LabVIEW Is there any way to look at the run state of a VI using VI Server or Scripting? Command Line Build. System Exec. LabVIEW Tutorials (by Vincent Lee) How Do I Debug My VI How Parallel Threads Work Tutorial How to Create Arrays on the Front Panel Tutorial How to Create Waveform Graphs Tutorial How to Create a Sub-VI Tutorial How to Initialize an Array Tutorial How to Pass Data Into and Out of a Loop Tutorial How to Replace an Array Subset Tutorial. One approach to program automation is to execute a program and pass arguments at the Command Line. , built applications). Programming We are programming a series of NXT cars to run a relay race using Bluetooth communication. Use regsvr32 to register the DLL in the command prompt: For 32-bit operating systems type regsvr32 dll_filename. LabVIEW requires a. vi module loaded: and below is the same module block diagram: The. You can use the Command Line Interface to send the desired information from an existing Python script into LabView code. To run this example, open a command line window. Not only does the semicolon suppress the output, it also speeds up processing, because output. Using the. To run an operation using the CLI for LabVIEW, execute a command with one or more of the following arguments. use vi to run the following ex command : | The UNIX and Linux Forums. Create a new VI whose front panel contains a waveform chart. With both the Raspberry Pi 2 Model B and the Beaglebone Black, you can actually deploy your LabVIEW VIs to the board and run with a computer to visualize your data or run headlessly. Figure 2b presents the Simulink model. The CLI for LabVIEW supports the following operations:. It should be possible to set up an externel merge tool by clicking tools > options > diff ? I can then set the path to the relevant VI's, but I am not sure this is the right approach?. Username or UID can be specified to. No more separate Run-Time Engine download. DLL software module. m files with an interactive command-line interface. When lvbld is run, it attempts to connect to LabVIEW using VI Server. 0 or later with Application Builder installed has this function available in \vi. If you want to execute multiple commands with 1 line, where you are starting the commands with start, for example, if you wanted to execute a command like this: start "" netsh dump && pause Then, you need to do it in 2 steps (one-line solution is at the end of this answer). The vmstat command will display statistics about system processes, memory, swap, I/O, and the CPU performance. Hi how do I use vi to do change some strings in a shell script loop 1. PID value 0 will be treated as process ID of top command itself. For other systems, you may need to select and run it from the contents of the library. LabVIEW is proprietary software for measurement and control systems, and is the hear of the NI design platform. 1,I want to run LabView from command prompt but I dont know how to do? How to call labview by DOS or command prompt vi. LabVIEW requires a. If you do not want to search for the entire command, place the cursor accordingly. For example, the following command line entry will launch LabVIEW 7. SPICE Command Line. Not only can it be used with the Android operating system, but it can also be easily used with National Instrument’s LabVIEW, as well as JAVA, Python, and other programming languages. In other words, after starting the command window and passing the command to it, LabVIEW will continue executing the next VI in your code while the command prompt window responds to the dir command. While we draw, we need to change some drafting settings. Ask Question Asked 5 years, 5 months ago. Is there any way to close that first cmd ? P. The main folder "GCS_LabVIEW" contains a terminal VI (for command based systems), a configuration VI (XXXX_Configuration_Setup. Benefits of a custom ini file Default Path. When a VI is running on the target with live front panel data on the dev PC, this is called Interactive Mode. Operating Operations Utilizing the Command Line Interface for LabView; NI LabView 2018 Torrent lets you run operations in LabView by executing instructions utilizing the command line interface (CLI) for LabView. exe, for example (actual mileage and paths may vary). From the VI to be opened in the Run-Time Environement, choose Tools>>OpenG Application Builder>>Open this VI in Run-Time. Bruevich (Podzorov group, Rutgers U. Simply open the command line by typing the word “run” into your Windows Start Menu, or execute the cmd. In case the command never being run, the data will be from the last reboot to the current time. You can use the Command Line Interface to send the desired information from an existing Python script into LabView code. LabVIEW is proprietary software for measurement and control systems, and is the hear of the NI design platform. The philosophy is that the C# application is very small but can be called directly by Jenkins or any other language and will then launch LabVIEW or our LabVIEW built. When the car reaches the finish line, it sends a message that starts the next car. 5 Open the LabVIEW® library "StampVI. See the example VI, Expert - Change Timeout. LabVIEW also has the traditional debugging tools, such as setting breakpoints, to display animated data and subroutine (VI) results, step and so on, debugging convenient program. 2 vi Chapter 5 explains how to run compiled applications on targets and VxWorks Command-Line Tools User's Guide, 6. Tip We recommend that you try to create your own files to get the most out of this exercise. Each VI is a wrapper over the appropriate function exported by the ACI. vi with XXXX being the PI product number of your system), a simple test VI, and, if available, several sample programs. Vi is a terminal application, so you'll have to start it from a terminal window. The latest version of LabVIEW Mac delivers speed improvements, new and improved features, and fixed bugs. Choose Blank VI once again to start a new VI. Updated: 12/29/2017 by Computer Hope. vi"" (or something like this). User-defined arguments start after two hyphens (- -) surrounded by spaces in the command line. Hi how do I use vi to do change some strings in a shell script loop 1. I use LabView7. 5; If reverting back to NI-SWITCH 1. This methodology could possibly be used in the Remove Backspace test harness. Keep in mind that if you will type this command in Start / Run Note you might get a notification for admin rights. LabVIEW for Raspberry Pi. But first thing is to introduce to using the keyboard to get around Windows and open the DOS box. vi initializes the motor by writing that motor to the VISA. However, this memory management is designed to be. The basic analogy throughout LabVIEW is that of a virtual instrument or VI. One approach to program automation is to execute a program and pass arguments at the Command Line. Product overview With the integration of OCD API and LabVIEW, developers will be able to easily write software diagnostic and test programs within LabVIEW for Wind River ICE and Wind River Probe, two industry-leading JTAG tools that provide solutions ranging from low-level hardware diagnostics and. We are trying to be able to send commands to the terminal prompt on the Pi 3 from the local Labview exe running on bootup just as if we were typing to the command line prompt ourselves. Getting Started - Open and Run a Virtual Instrument In this part of the pre-lab you will examine the DSP First Demo VI and run it. reporting success or failure of labview command line build We've set up a nightly build for our project, using a batch file for compiling the C++ code in our project on Windows. How many times does the for-loop run? 19 20 21 7. The CLI for LabVIEW supports the following operations:. exe LEP_AutoTest_RunAll. VI and 4_Thermometers. Review the instructions on Bluetooth pairing here. 1,I want to run LabView from command prompt but I dont know how to do? How to call labview by DOS or command prompt vi. vi using the NI Example Finder in LabVIEW. When the command prompt changes to '[email protected]' you are in the chroot so that is good, however before you run the 'ln -s' command you need to navigate to the /usr/lib directory. LabVIEW relies on graphical symbols rather than textual language to describe programming actions The principle of dataflow, in which functions execute only after receiving the necessary data, governs execution in a straightforward manner. From here you can examine the file system and run other commands in the same environment that the LabVIEW run-time engine is running in. vi new line commands. Learn How to interface 3 Axis Industrial Vibration sensor with any PC. Any LabVIEW version 8. This site provides all sorts of documentation sourced from windows help files. Labview Exercises for Labview 7. exe command must be run from a Command Prompt: cd modpoll win\modpoll -h Linux Download into a folder. Using this method, LabVIEW and the command prompt window will run asynchronously. LabVIEW also has the traditional debugging tools, such as setting breakpoints, to display animated data and subroutine (VI) results, step and so on, debugging convenient program. Vi is a terminal application, so you'll have to start it from a terminal window. LabVIEW IoT Education Kit. If I try to use this and other vis the compiler just hangs up. vi manually later. This directory is. If you want a VI to read the command line, let me know your email address. It is possible to use the command mode of ex from within vi and to use the command mode of vi from within ex. Related Example in Driver: Timer Calibration. With LabVIEW MathScript RT Module you can: • Deploy your custom. This help system includes information about LabVIEW programming concepts, step-by-step instructions for using LabVIEW, and reference information about LabVIEW VIs, functions, palettes, menus, and tools. However, a GPIB Read returns nothing. The LabVIEW-CLI can be used to automate the launch of NI Unit Test Framework >labview-cli --kill --lv-ver 2014 “Run UTF Tests. lvproj” “UTF. The young rice plants were bedded regularly ridged line in the paddy fields by the machine. " Figure 1 - Opening the Command Prompt in elevated mode (clockwise from top left, Windows XP, 7, 8 & 10) 3. You can clicky-clicky all you want and waste hours of of your life pushing your mouse around the screen. To run this example, open a command line window. The information, tables, diagrams, and photographs contained herein are the property of Dataforth Corporation. This allows the LV run-time to be installed and run safely on many different Linux operating systems. "System Exec. yw yank from cursor to end of current word. It consists in an executable and is able to import your existing LabVIEW application source code and add many features to your application, almost without requiring you to write any code. Search for cmd. exe and get the PID (Process ID) for the cmd. LabVIEW) is similar to Active X controls in LabVIEW Two tactics: • Save text file to disk, open Excel from start menu, open file • Save text file to disk, use LabVIEW to run EXCEL from DOS command line. UNIX: vi Editor General Introduction The vi editor (short for visual editor) is a screen editor which is available on almost all Unix systems. Use the TypeSpecialization structure to customize sections of code in amalleable VI for specific data types. I have to develop one application to communicate with my hardware. Open the demo_ishapes. Command Line. LabVIEW is a graphical programming language that uses icons instead of lines of text to create full-featured test and measurement applications. On Robot Project Center, under Choose NXT/EV3, choose your NXT brick or use Find NXT/EV3 to connect to your NXT brick. exe to be called it works fine. with v, V, or Ctrl-v), and vim is helpfully prefixing the markers for 'beginning of selection' through 'end of selection' in order to apply those limitations to the scope of the command you are presumably about to enter. View; View source; History; More. When the car reaches the finish line, it sends a message that starts the next car. Make sure to save the VI before opening it in the Run-Time environement. LabView can be used to execute a python script via command line and receive feedback from that command line interface. vi & Visual Noise. LabVIEW examples for NI-VISA are located in the labview\examples\Instrument IO\VISA directory. If you can't find anything in Labview to read the dynnamic environment varialbles take a look at Python before buying an add on module for your version of Labview. accessible on the NXT front panel, and you can run it from the NXT itself without the computer connected. , built applications). Opening a VI in the LabVIEW Run-Time Environment From the LabVIEW pull-down menu. exe file at C:\Windows\System32\cmd. Using them it's possible to read and write to any VIO component in a DOS-prompt. Hi how do I use vi to do change some strings in a shell script loop 1. It is very easy, then, for LabVIEW to take that selection from one screen, which we'll call the "Configure Test" screen/VI, pass that selection to a "Run Test" VI, and execute the appropriate set of code. See the VI Tester documentation for more information on creating new tests. To launch a VI from the command line (such as by selecting Start»Run on Windows), use the following syntax:. A) Timer Calibration. In LabVIEW 6. Run External Commands, Scripts, and Programs. LabVIEW for Raspberry Pi. zip file) below includes a version of their library and some example VI's that read/write the T7 or T4's test registers:. vi included with this tutorial. Known in LabVIEW as dynamic dispatch (DD), run-time polymorphism allows classes to call specific method implementations on the fly, while a VI is running. You can have the executable run in different ways, depending on the arguments given in the command line. Once you have learned vi, you will find that it is a fast and powerful editor. VI Package Manager (VIPM) Getting Started Using VIPM How to manually configure your LabVIEW version to allow VIPM communication. I will also cover some handy hints & tips when setting up the Raspberry Pi. Here is a vi. Open Excel from START menu Excel_ex2 ­ simple text input example Open Excel from LabVIEW DOS. Ching Could you please provide some examples on calling the tools from command line? "LabView. The content of the - rsscope Configure TV Trigger. Come browse our large digital warehouse of free sample essays. [1] Only if is 1 (on) and is 23, Tera Term starts spontaneously sending telnet commands to the host for the option negotiation when the TCP/IP connection is established. You may need to change the color of the line so that it is visible. What is VI Editor. This image is a LabVIEW snippet, which includes LabVIEW code that you can reuse in your project. You've already seen from Chapter 9, "Exploring Strings and File I/O," the most common file I/O functions LabVIEW has to offer. Entering Text. Ctrl-Up arrow. exe "[path to VI]" -- [user arguments] Build VI must be set to "Run When Opened" PUSHING THE20 LIMITS OF LABVIEW. Operating Operations Utilizing the Command Line Interface for LabView; NI LabView 2018 Torrent lets you run operations in LabView by executing instructions utilizing the command line interface (CLI) for LabView. Silent command-line install support. Here is a simple calculation: 1+2. This is a screenshot of DebugView capturing Win32 debug output from a remote system. You can also set your VI to run on startup so that each time you power on the RPI it will run your VI without a computer!. To run this example, open a command line window. There is currently no option to perform these actions via command-line without having VIPM running. Windows Explorer. Just pass the path of the batch file into the command input of System Exec and run the vi. vi using the NI Example Finder in LabVIEW. Run ls first, for each file that contains the word salesreport*. The vmstat command will display statistics about system processes, memory, swap, I/O, and the CPU performance. Note the presence of a highlighting filter. $ top -p pid_value 28) Display task per username or UID in command line. Use the vi /path/to/file command to open an existing file with Vi. Choose your PWM line and name your motor. It's easy to create a password protected text file by using the command line text editor 'vi'. Introduction to LabVIEW. It is possible to use the command mode of ex from within vi and to use the command mode of vi from within ex. The example. Reverting to NI-SWITCH 1. Not only can it be used with the Android operating system, but it can also be easily used with National Instrument’s LabVIEW, as well as JAVA, Python, and other programming languages. MATLAB and Simulink are automatically launched with the start of LabVIEW VI, through a command-line exec node. It is very easy, then, for LabVIEW to take that selection from one screen, which we'll call the "Configure Test" screen/VI, pass that selection to a "Run Test" VI, and execute the appropriate set of code. Instructions - Carefully work through each of the following examples. What driver should I use when connecting WT500/WT1800 via USB from NI LabVIEW Environment? How do I Measure Inrush Current on the WT1800? Xviewer Cannot Open DL850V Binary File and Displays "Remote Procedure Call Failed" Error; Can Xviewer. How to open a file in Excel from the command line. DX5100 / LabView Library PromLegion Ltd ver. Ask Question Asked 5 years, 5 months ago. To assist in handling line endings from various environments, we now have Normalize End Of Line. The modpoll. Choose your PWM line and name your motor. When the command prompt changes to '[email protected]' you are in the chroot so that is good, however before you run the 'ln -s' command you need to navigate to the /usr/lib directory. vi - 'Line Field. These files can be found by mapping a network drive to \\poohbah\labview, and by running the ‗autorun' file in the ‗Labview 7' folder. The thing is I need to do it from an external application -the application should issue a command to start recording and then to stop it. When you are prompted for the. Pause—Pauses or resumes execution. The content of the RSZVB Import Trace as Limit Line. Ctrl-Down arrow Moves key focus inside an array or cluster, when used while VI is running. Silent command-line install support. The user can use the Aardvark LabVIEW Driver to control the Aardvark adapter, and to write a custom program to achieve his goals. exe; If you run the original VIs you will have full privileges to examine and edit the LabVIEW code. Any LabVIEW version 8. What is VI Editor. This image is a LabVIEW snippet, which includes LabVIEW code that you can reuse in your project. To assist in handling line endings from various environments, we now have Normalize End Of Line. You can then run the function or read and write to the variables which are attached. exe, for example (actual mileage and paths may vary). Note: The run command executes on a line-by-line basis. Contents Educational Objectives Introduction. Otherwise, I was wondering whether you would be able to add your executables in LabVIEW 2011 to your bitbucket downloads. One approach to program automation is to execute a program and pass arguments at the Command Line. Before you run the program, check the circuit connections. Labview is a software programming tool which allows for the design and implementation of virtual instrumentation. smooth line. vi manually later. The LabVIEW-CLI can be used to automate the launch of NI Unit Test Framework >labview-cli --kill --lv-ver 2014 “Run UTF Tests. The result is 3 (as you might have guessed) which is assigned to the standard variable ans (short for answer). If you run the executable, you will not be able to examine or edit the code. Note: LabVIEW VI Scripting is installed by default on LabVIEW 2010 and later. Programs in LabVIEW are called virtual instruments (VIs) and integrate a graphical user interface (GUI) with the development of code. d^ (d caret, not CTRL d) Delete to beginning of line. You can also use "run as" from the command line via Command Prompt. Click the button to list errors. Since we are still using LabVIEW 2011 in our company, I was wondering whether your executable (run with 2016 LV Run-Time Engine) would work with the LabVIEW 2011 Compare and Merge tools. The LabVIEW Professional Development System is recommended for professional software development that requires code quality review, unit testing,. For other systems, you may need to select and run it from the contents of the library. Hello All, I would like to know if there is a way to run a java program, requiring administrator priviledges, via the Windows command line. The AndroiDAQ module was designed as an easy to use and complete data acquisition module for multiple platforms. Overview The LabVIEW Virtual Instruments for TRACE32 contains an interface that gives the LabVIEW internal VIs access to external hardware debuggers. vi manually later. Add different parameters and commands then click OK to update the sequence. RE: Run Windows Apps with Labview 6 analogkid2digitalman (Electrical) 17 Mar 05 17:38 Use the System Exec vi, (in the communications palette) with a command line of c:\winnt\system32\notepad.